A gas bottle lasts the energy left in it divided by what your appliances use: each kilogram of LPG holds about 12.9 kWh, and an appliance uses its rated kW for each hour it runs on full. For example, a full 6 kg bottle running one 3.5 kW appliance on full lasts about 22 hours.
How the estimate works
A gas bottle is a store of energy, and every appliance draws on it at a rate given by its power. The calculator turns the gas left into kilowatt hours at 12.9 per kilogram, adds up what your appliances would use in a day, and divides one by the other.
Nobody runs everything flat out all the time, and nobody can say exactly how far you will turn it down. So there are two figures: one with every appliance on full for the hours you gave, and one with them at the lower setting you chose. Plan on the first.
The ruler beside the bottle is marked in days of your pattern at full power. Add an appliance and the same level of gas becomes fewer days.
Worked examples
A full 6 kg bottle and one 3.5 kW appliance
It burns about 271 g an hour on full, so the bottle holds 22 hours at full power and about 44 at half.
Four nights with cooking and heating
A 3 kW cooker for an hour and a half and a 2 kW heater for five hours use 14.5 kWh a day on full. A full 6 kg bottle lasts 5.3 to 10 days, which covers four days even if both run on full for the hours given. Longer cold evenings with the heater on would eat that margin.
A part-used bottle weighed on bathroom scales
The label says empty weight 7.4 kg and the scales read 9.9 kg, leaving 2.5 kg of gas. Running a 3 kW appliance for two hours a day, that is 5.4 to 10 days.
What changes the result
- Heating. Space heaters often run for hours and usually dominate the total. Cooking is short by comparison.
- The setting and the weather. Cold and wind mean longer, harder running.
- Accuracy of the weighing. Home scales can be out by several hundred grams, which matters when a bottle is nearly empty.
- The last of the gas. As a bottle empties, and especially in the cold, a heavy load may falter before it is truly empty. Keep a margin.
- Appliance rating. Some plates quote net and some gross heat input, which differ by several per cent. A figure in grams per hour avoids the question.
UK context
Bottles come in many sizes and in different brands with their own fittings, so use the gas weight printed on yours. The usual UK colours differ between brands, so read the label and do not go by colour alone. Use the right regulator for the system, check hoses for age and damage, store spare cylinders upright and outdoors in a ventilated place away from drains and hollows, because LPG is heavier than air, and have caravan and boat gas installations serviced by someone qualified.
For a park home in England that is your only or main home, keep gas apart from the pitch fee when you check a bill. Under the Mobile Homes Act 1983 (paragraph 29, checked 26 November 2026), the pitch fee does not include amounts due for gas unless your agreement expressly says it does. If you have a pitch fee review notice, you can check the park home pitch fee increase. These terms do not apply to pitches on council Gypsy and Traveller sites.
Assumptions and sources
| Assumption | Value used | Source |
|---|---|---|
| Energy in LPG | 12.9 kWh per kg, used for both propane and butane | Forest Research, typical calorific values of fuels (reference table as published; checked 25 November 2026); using one figure for both is this page’s simplification |
| Butane in the cold | Less gas below about 4 °C | Camping and Caravanning Club, Gas for caravans, campervans and motorhomes (guide as published; checked 25 November 2026) |
| Carbon monoxide | Warning only; not calculated | HSE, Carbon monoxide awareness: frequently asked questions (page as published; checked 25 November 2026) |
| Appliance power and lower setting | Entered by you; starting values of 3 kW, 1.8 kW, 4 kW and 50% are examples | This page’s placeholders, set 25 November 2026 |
Common questions
How do I tell how much gas is left in the bottle?
Weigh it. Many cylinders are stamped or labelled with their empty weight, often shown as tare or TW. Subtract that from what the scales read and the difference is the gas left, in kilograms. Check how your cylinder is marked, keep it upright, and do not disconnect or move it while anything is lit.
How much gas does an appliance use in an hour?
Divide its heat input in kilowatts by 12.9, the kilowatt hours in a kilogram of LPG from Forest Research. A 3.5 kW appliance on full uses about 271 g an hour. If the data plate gives grams per hour directly, trust that.
Why does my butane run out of puff in cold weather?
The Camping and Caravanning Club says butane begins to produce less gas below about 4 °C, while propane can be used below freezing. For autumn and winter use, propane is the usual choice, with the correct regulator.
Can I use a gas heater or barbecue inside a tent, shed or caravan awning?
Do not bring appliances made for outdoors into enclosed spaces. HSE warns that carbon monoxide from fuel that does not burn properly has no colour, smell or taste and can kill quickly. Use only appliances designed for the space, with the ventilation they need, and fit a carbon monoxide alarm.
Why is my bottle running out faster than the estimate?
Appliances are often run harder than expected, wind makes outdoor burners work longer, and a leak is possible. If you smell gas, turn the cylinder off, ventilate, avoid flames and switches, and get the system checked.
What should I enter if I do not know the kilowatts?
Look for the data plate or the manual. The starting figures on this page are only examples. Guessing changes the answer in direct proportion: twice the kilowatts, half the time.
Related calculators
Page last checked 25 November 2026.