Immersion heater timer: what each setting costs

Push the hours in or out and watch the tank. Costs use Ofgem's capped electricity rate until you enter your own.

Timer: tick the hours the heater may run

Night and morning

Afternoon and evening

60°45°20°00:0006:0012:0018:0000:00

Line: tank temperature. Amber blocks: element heating. Drops: hot water drawn at 07:00 and 19:00.

£1.63 to £1.67 a day

About £595 to £610 a year if every day looked like this, using 6.2 to 6.3 kWh a day.

The water is likely to run cool: the tank is under 45 °C before one of your draws, or cannot supply all of it. Add an hour before that draw.

Your cylinder and use

Four settings on your figures

Setting (press to load)A dayA yearHot water
£1.96 to £2.21£715 to £805Stays hot enough
£1.63 to £1.67£595 to £610May run cool
£1.76 to £1.89£645 to £690Stays hot enough
£1.70 to £1.80£620 to £655May run cool

A timer only saves the heat a hot water cylinder leaks while it sits hot, not the hot water you draw, so heating shortly before you need it costs less than leaving the immersion on all day. For example, a 120 litre cylinder with older foam left on all day costs about £1.96 to £2.21 a day at 26.32p a kWh.

How the timer model works

Your bill for hot water has two parts. One is the heat that leaves through the taps. That is fixed by how much you use. The other is the standing loss: heat that leaks from the cylinder whether or not anyone runs a tap. A timer can only change the second part and the hour at which you buy the first.

The page simulates the tank in five minute steps. Heat leaks in proportion to how far the water is above a 20 °C room. Hot water is drawn at 07:00 and 19:00 and replaced from a 10 °C cold supply. The element runs only in ticked hours and stops when the tank reaches 60 °C. After two weeks of repeating days it reports the last day.

The size of the leak starts from a published limit. The Scottish building services compliance guide says unvented cylinders heated mainly by electricity should lose no more than 1.15 × (0.2 + 0.051 × V2/3) kWh a day, where V is the volume in litres. For 120 litres that is 1.66 kWh. A good modern cylinder may do better than the limit and an old or badly lagged one can do much worse, so each insulation choice is a range of multiples of that figure.

Read the saving as an upper estimate. The model mixes the tank evenly. A real cylinder keeps the hottest water at the top and lets cold in underneath, so after a morning shower the taps may stay hotter for longer than the line shows, and the hot layer at the top goes on losing heat. Both mean a real timer may save less than modelled, and the cool-water warning may be cautious.

The temperature trace shows the leakier end of your range, because it is the cautious one for deciding whether the water stays hot.

Worked examples

120 litres, older foam, 100 litres of hot water a day, 26.32p

Left on all day the model gives £1.96 to £2.21 a day, or £715 to £805 a year. A morning and afternoon boost gives £1.76 to £1.89 and keeps enough heat for the evening. A single morning boost is cheaper still at £1.63 to £1.67, but it leaves the tank cool by evening, which is why it is flagged.

The same home from January 2027 at 32.69p

On all day becomes £2.43 to £2.75 a day, and morning and afternoon £2.19 to £2.35. The gap in pounds grows with the unit rate because the kilowatt hours do not change.

Why insulation matters more than the timer in a leaky tank

Left on all day with thin or patchy lagging, the model gives £805 to £945 a year; with a good modern cylinder, £685 to £715. The first move with a bare or badly wrapped cylinder is usually to insulate it properly, following the cylinder and heater maker's instructions about keeping electrical covers accessible.

What changes the result

UK context and safety

Many UK flats and off-gas homes rely on an immersion heater, often on a two-rate meter with a separate lower element for the cheap hours. If you have two elements, check which switch does what before changing timer settings, and ask your supplier what hours your meter treats as off-peak, including whether they shift with the clocks.

Do not remove covers or adjust a thermostat unless you are competent to do so: immersion heaters are mains electrical equipment in contact with water. Anything that trips, leaks, smells hot or gives water far hotter or colder than usual needs an electrician or plumber.

From 1 October 2026 to 30 June 2027 Ofgem states there is no VAT on electricity. The January 2027 rate is a separate cap period; check Ofgem or your bill for what applies later.

Assumptions and sources

AssumptionValue usedSource
Electricity rate, 1 October to 31 December 202626.32p per kWh, average capped single rate, Direct DebitOfgem, Energy price cap unit rates and standing charges (periods 1 October to 31 December 2026 and 1 January to 31 March 2027; checked 25 November 2026)
Electricity rate, 1 January to 31 March 202732.69p per kWh, same basis; regional rates differOfgem, Energy price cap unit rates and standing charges (periods 1 October to 31 December 2026 and 1 January to 31 March 2027; checked 25 November 2026)
Standing loss starting point1.15 × (0.2 + 0.051V2/3) kWh a dayScottish Government, Domestic Building Services Compliance Guide for Scotland (2022 edition, June 2022; checked 25 November 2026), the limit for electrically heated unvented cylinders
Storage temperature60 °CHSE, Managing legionella in hot and cold water systems (guidance page as published; checked 25 November 2026)
Insulation rangesFactory foam, in good condition: 0.8 to 1 times the figure above; Older foam, or unsure: 1 to 1.6 times the figure above; Loose jacket, thin or patchy lagging: 1.6 to 2.5 times the figure aboveThis page's own assumption, set 25 November 2026
TemperaturesCold supply 10 °C, room around cylinder 20 °C, the loss figure applied at a 40 degree difference, comfortable minimum 45 °CThis page's own assumptions
Tank behaviourEvenly mixed, two draws a day, no pipe losses, no stratification. Each draw takes the same heat even when the tank is cooler, as if you ran more waterThis page's own simplification
Energy to heat water4.186 kJ per litre per degree; 3,600 kJ per kWhStandard physical constants

No standing charge is included, because you pay it whether or not the heater runs.

Common questions

How much does it cost to heat a tank with an immersion heater?

Heating 120 litres from 10 to 60 °C takes about 7.0 kWh. At Ofgem's average capped single rate that is about £1.84 for October to December 2026 (26.32p) and £2.28 for January to March 2027 (32.69p). Your region and tariff can differ, so use the unit rate on your bill.

Is it cheaper to leave the immersion heater on all the time?

Not in this model. A thermostat stops the water getting hotter than its setting, but a tank held hot all day keeps losing heat and keeps being topped up. Letting it cool between boosts loses less. The saving depends on how well the cylinder is insulated and is often modest with a good one.

How long should the immersion heater be on each day?

Long enough to replace what you draw plus what the cylinder loses. A 3 kW element adds about 3 kWh an hour. Use the timer above: add hours until the warnings clear, then check the result against real life for a few days.

What temperature should the cylinder be set to?

HSE guidance on hot and cold water systems says hot water should be stored at least at 60 °C. Water that hot can scald, so think about who uses the taps and whether blending valves are needed. Ask a qualified person before changing a thermostat.

Does switching off at the wall save more than a timer?

The saving comes from the hours the element cannot run, however you achieve it. A timer does it reliably. A wall switch relies on someone remembering, both to turn it off and to turn it on in time.

Is Economy 7 worth it for hot water?

It depends on your two rates and on whether one overnight heat covers the day. Choose the two-rate option, enter the rates and the start of your cheap period from your bill or meter, then compare. Peak units for everything else in the home also cost more on many two-rate tariffs, which this page does not include.

Why do my meter readings differ from the estimate?

The model treats the tank as evenly mixed and your hot water as two fixed draws. Real cylinders keep hot water at the top, pipes lose heat too, thermostats are not exact and every day is different.

Related calculators

Page last checked 25 November 2026.